Hanna Instruments GroLine Direct Soil and Soilless Media pH Electrode
Follow This Simple Feed Chart Designed by our Research Team
| Reference | Single, Ag/AgCl |
|---|---|
| Junction / Flow Rate | Ceramic, triple / 40-50 µL/h |
| Electrolyte | KCl 3.5M + AgCl |
| Max Pressure | 0.1 bar |
| Range | pH: 0 to 12 |
| Recommended Operating Temperature | -5 to 70°C (23 to 158°F) – LT |
| Tip / Shape | Conic (12 x 12 mm) |
| Temperature Sensor | Yes |
|---|---|
| Amplifier | Yes |
| Body Materia | Glass |
| Cable | 7-pole; 1 m (3.3’) |
| Recommended Use | Direct soil, Soilless media, Soil solution |
| Connection | Quick Connect DIN* |
| Special Note | * Only for use with HI9814 GroLine multiparameter meter |
The Hanna Instruments GroLine Direct Soil and Soilless Media pH Electrode is a pH electrode for the direct measurement of pH in soil and soilless media.
The Hanna Instruments GroLine Direct Soil and Soilless Media pH Electrode has a glass body, is refillable, and has a DIN connector. It is compatible with the HI9814 Groline portable pH/EC/TDS metre. The exterior reference cell of this electrode includes a triple ceramic connection, while the conic pH sensor tip is constructed of low temperature glass. For temperature compensated pH readings, an integrated amplifier and temperature sensor are included. The HI12943 is designed for pH readings in soils and hydroponics growth medium such as rockwool, coconut cour, perlite, and other soilless substrates. Hanna Instruments GroLine Direct Soil and Soilless Media pH Electrode
The HI12943 can only be used with Hanna’s HI9814 Groline portable pH/EC/TDS meter. *HI1293 is replacing HI1294D. Both electrodes are compatible with existing models of HI9814. Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference, and electrolyte used are just some of the design considerations. The HI12943 uses low temperature (LT) glass, conic bulb, glass body, triple ceramic junction, and is refillable with 3.5M KCl + AgCl.
Low-Temperature Glass Formulation
The glass tip uses a special LT glass formulation with a lower resistance of approximately 50 megaohms compared to general purpose (GP) with a resistance of about 100 megaohms. As the temperature of the glass decreases when in a sample at low temperature, the resistance of the LT glass will increase approaching that of GP glass at ambient temperatures. If using GP glass, the resistance would increase above the optimum resistance for the high impedance input of a pH meter. The HI12943 is suitable to use with samples that measure from -5 to 70C.
Conic Bulb
The conical shaped tip design allows for penetration into solids, semi-solids, and emulsions. The HI12943 is ideal for the direct measurement of pH in soils and soil slurries.
Glass Body
The glass of the HI12943 is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium the steadier the reference potential.
Triple Ceramic Junction
The triple ceramic junction allows a higher flow rate of electrolyte from the reference cell into the measurement sample. A typical pH electrode will have a single ceramic junction that flow rate of 15 to 20 µL/hour. The HI12943 has three ceramic junctions in contact with the sample providing for a flow rate of 40 to 50 µL/hour. The increased flow provides a greater continuity between the reference electrode and the indicating electrode. Hanna Instruments GroLine Direct Soil and Soilless Media pH Electrode
Refillable
The HI12943 is a refillable probe. Since it is a single junction pH electrode the fill solution is the HI7071 3.5M KCl + AgCl. If using a refillable pH electrode, the fill cap should be removed prior to calibration and measurement. Removing the cap creates positive head pressure in the reference cell allowing for a higher flow rate of electrolyte through the outer junction. A higher flow rate will result in a faster and more stable reading.
Quick DIN Connector
The HI12943 has a Quick DIN connector for use with the HI9814 GroLine portable pH/t/EC/TDS meter.
NOTE: *HI1293 is replacing HI1294D. Both electrodes are compatible with existing models of HI9814




Adam (verified owner) –
FarmHydroSupplies has become my number one supplier for hydroponic products; their exceptional shipping services ensure they deliver high-quality products in a timely manner.
Christopher (verified owner) –
FarmHydroSupplies has consistently provided excellent shipping services; their attention to detail and quick order processing make them my preferred choice.
Grayson (verified owner) –
The shipping process with FarmHydroSupplies was seamless; my order arrived promptly and in excellent condition.
Simon (verified owner) –
I trust FarmHydroSupplies wholeheartedly when it comes to shipping; their track record of delivering products on time and in good condition is commendable.
Owen (verified owner) –
FarmHydroSupplies has earned my trust as a reliable shipping partner; they consistently go above and beyond to ensure my orders arrive on time and in excellent condition.
Noah (verified owner) –
FarmHydroSupplies has consistently provided excellent shipping services; their attention to detail and quick order processing make them my preferred choice.