TrolMaster Carbon-X CO2 Alarm System
CO2 Alarm System from TrolMaster provides critical monitoring of CO2 levels for up to 13 separate zones / rooms.
Here, The TrolMaster Carbon-X system is intende to safeguard consumers. And workers in close proximity to commercial indoor growing spaces that use supplementary CO2. While also complying with all local and state requirements. The system features a modular structure that allows you to configure it to meet your specific needs. And it can monitor up to 13 zones.
The Carbon-X system provides both high level and low level notifications. The CO2 levels in the locations will be regularly monitore by the sensors. If dangerous CO2 levels are detecte. Further, the system may switch off CO2 flow, vent the space, activate visual and auditory alarms, and even transmit signals to a fire alarm panel.
The TrolMaster Carbon-X system provides critical monitoring of CO2 levels for up to 13 separate zones / rooms. The system can have both high level (up to 30,000ppm) alerts. As well as low level (5,000ppm) alerts. Both high and low level limits are user-adjustable to meet local regulations for supplemental CO2 use indoors.
Whats Includd
x1 CO2 Controller (CDA-1)
x2 16 ft. RJ12 Cable
TrolMaster Carbon-X CO2 Alarm System
x1 12 Volt Power Adapter

The Carbon-X system can also control various devices such as ventilation fans, dampers. Main CO2 valves as well as to send a signal to the fire department by interfacing to the fire / alarm panel in the facility. Automatic shut-off of CO2 is accomplishd by wiring the facility’s main CO2 solenoid in series with one of the system control modules. The settings for each of the devices connecte to the system are user-selectable for easy customization.
Each room monitore by the Carbon-X will also require an audio-visual alarm to alert the personnel to the level of CO2 in the area. And whether or not it is safe to occupy the area.
The TrolMaster app can be use to remotely monitor the Carbon-X as well as to receive user-alert / notifications in the case of high CO2 levels are detected.
The system can control up to 40 outputs total. Each output can be linked to an individual sensor. Or all sensors for a customized programming. There are five types of outputs that can be connecte to the system.
AS-1 The AS-1 CO2 Alarm Station is an audio/visual alarm to be mounte inside. Or outside the room to be monitore, and sound an alarm (both visible and audible) in the event of the CO2 level going above normal or safe levels. It can be linked to either low or the high level CO2 sensors, or it can be linke to both sensors for complete redundancy.
AS-2 The AS-2 CO2 Alarm Station combines an audio-visual alarm module with a color-code LED display indicator and a LCD digital ppm level reading. It is designe to be mounte outside of the space to be monitord, and will display the CO2 ppm level. The DSA-1 can be linked to either the low or the high level CO2 sensors, or it can linked to both sensors for complete redundancy.
DSE-1 The DSE-1 CO2 Emergency Stop Station controls the main Co2 solenoid. It will automatically shut it off if any fault or high CO2 level is detected
DSC-1 The DSC-1 is a 120V controlld outlet that turns on devices like ventilation fans if any fault or high CO2 level is detecte.
DSD-1 The DSD-1 is a Dry Contact output. Both N/O and N/C connections are provide on the DSD-1 and it can interface to the fire alarm panel.